ELECTRIC OVENS


BATCH Type Ovens
– Horizontal Air Flow
   Front to Back
      COF – 650°F
      COFM – 850°F
      COFH – 1200°F
      COFVH – 1400°F
– Horizontal Air Flow
   Side to Side
      HCC – 650°F
– Vertical Air Flow
      M2-WOF – 650°F
      MTOF – 850°F
      HTOF – 1200°F
– Gravity Convection Air Flow
      M2-WO – 650°F

BELL TYPE Ovens
Radiant Heat
      RBO – 1000°F
      RBOF – 1000°F
Recirculating Air Flow
      BOF – 650°F
      BOFM – 850°F
      BOFH – 1200°F

PIT TYPE Ovens
– Radiant Heat
      RPO – 1000°F
– Recirculating Air Flow
      VOFB – 850°F

TOP LOADING Ovens
      TLO – 1200°F
      TLOD – 1000°F

WALK-IN Ovens
Horizontal Air Flow
      ROFH – 450°F
      LOFH – 650°F
      LOFHM – 850°F
Vertical Air Flow
      ROFV – 450°F
      LOFV – 650°F
      LOFVM – 850°F

UTILITY Ovens
    UOF – 400°F 

                          

DOWNLOAD OUR
ELECTRIC OVENS BULLETIN


TRENT, Inc.
201 Leverington Ave.
Philadelphia, PA 19127
Toll Free: 800-544-TRENT
Phone: 215-482-5000
Fax: 215-482-9389

 

©2005 Trent, Inc.

 

privacy notice

 

 

 

 

Maximum Temperature: 650°F, 850°F, 1000°F

TRENT BOF, BOFM and BOFH Ovens are designed with square work chambers and insulation of varying thickness depending on the temperature range. The outer casing is heavy gauge reinforced steel construction and the inner liner is aluminized steel with work chamber access through the open bottom which sits on an insulated hearth. TRENT Folded and Formed® heating elements are mounted to two of the side walls in alloy steel heater racks and use direct drive motors with a recirculating fan.

The oven lift framework is constructed with steel tubular members and is fully reinforced for rigidity. The oven assembly is raised and lowered manually using a counterweighted pulley and rope system. Pneumatic cylinders and automatic controls can be added as optional extras if required.

The ceiling mounted recirculating fan, located behind an aluminized steel baffle, draws air around and through the load in the work chamber in a vertical plane with circulation from bottom to top. The air is forced behind the fan baffle to the side walls where it passes downward over the heating elements located in the side wall ducting. The side wall ducting also acts as a baffle to prevent direct radiation to the process load.

Select from the standard sizes below or ask us to design one to fit your specific requirements.

STANDARD FEATURES:
• Standard parts with little or no maintenance required
• Heavy duty steel exterior for industrial applications
• Vertical air circulation
• Direct drive fan and motor
• Aluminized steel interior and air flow baffles
• Tubular steel lift stand with aluminized steel hearth and counterweighted
   lifting mechanism for manual operation
• Adjustable blast gates for air intake and exhaust
• Mineral wool blanket and block type insulation
TRENT Folded and Formed® heater racks for long life and good control

OPTIONS:
• Switch gear and control package
• Air cylinder lifting mechanism
• Special purpose accessories